Charge Controller Configuration Over Bluetooth
This document outlines configuration steps for installing the Victron Energy BlueSolar MPPT 75/15 and the Victron Energy SmartSolar MPPT 75/15 charge controllers.


About
The charge controller comes preconfigured with a load output mode that isn't optimal for Motus stations and should be changed. In addition, the default charging profile is designed for AGM Lead Acid batteries so it should be switched to Lithium Iron Phosphate if you are using that chemistry.
Prerequisites
VE.Direct Bluetooth Smart Dongle (if working with Victron Energy BlueSolar MPPT 75/15)
Instructions
Connecting for the first time
The charge controller needs to be connected to a battery in order to connect to it.
Remove the jumper and discard it (circled in red).

Setting the Load Output Mode
Go to the settings (gear icon, top-right).

Select "Load output".

Change "Operation mode" to "Conv. algorithm 1".


Setting Battery Type to Lithium
Go to the settings (gear icon, top-right).

Select "Battery".

Press the dropdown arrow next to "Battery preset" then "Select preset".


Select "Smart Lithium"

Turning off "Streetlight Mode"
Go to the settings (gear icon, top-right).

Select "Streetlight".

Make sure the toggle is in the off position.