# Beacon tags

### Description

Beacon tags, sometimes called sentinel tags, are a special kind of tag used primarily for confirming a station's operation over time.&#x20;

They differ from typical tags in that all physical beacon tags share identical properties and cannot be distinguished from one another. They use dedicated manufacturer codes that are used only for beacon tags, and, in the case of Lotek, is used for each of the various frequencies worldwide.

| Manufacturer | Dedicated beacon tag code | Burst interval | Frequencies                      |
| ------------ | ------------------------- | -------------- | -------------------------------- |
| Lotek        | 732                       | 40 seconds     | 166.38 MHz, 150.1 MHz, 151.5 MHz |
| CTT          | 78554C33                  | 5 seconds      | 434 MHz                          |

### Registration and metadata management

Because all physical beacon tags are essentially identical, they are not registered or managed as typical tags are. Instead, all tags with the same properties share a single registration and deployment record in **Project 322** ([new explore pages](https://motus.org/dashboard/#e=profile\&d=projects\&s=322); [old explore pages](https://motus.org/data/projectTags?id=322)). Beyond confirming that the beacon tag you have exists in this project, there is no further metadata management required in order to use a beacon tag.

{% hint style="info" %}
Prior to settling on dedicated tag codes to use for beacon tags, there were several earlier cases where multiple physical tags were issued with identical properties. These were also registered to Project 322 and many of these remain active.
{% endhint %}

### Usage

Ideally, a beacon tag would not be placed too close to a receiver lest the tags' signal may be picked up directly by a dongle. This could lead to a situation where the antenna and cable assembly is not functioning, yet it appears to be working fine due to the signal being picked up directly by dongle. In practice, it's often impossible to place the beacon tag at the "perfect" distance from a particular station.


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.motus.org/en/tags/appendix/beacon-tags.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.